Beam-Column Timber Joint Connection Behavior Due to Nail and Modified-Washer Reinforcement Tests

Pranata, Yosafat Aji and Kristianto, Anang and Pattipawaej, Olga Catherina (2019) Beam-Column Timber Joint Connection Behavior Due to Nail and Modified-Washer Reinforcement Tests. Wood Research Journal, 10 (1). pp. 6-10. ISSN 2774-9320

[img] Text
2. Beam-Column Timber Joint Connection_Lengkap.pdf

Download (1211Kb)
[img] Text
2. Paper Wood Research Journal 2019 Turnitin.pdf

Download (1567Kb)

Abstract

Timber connection capacity, in case of beam-column joint connection provides significant impact on the wooden building structures. Strength and stiffness of timber connections using reinforcement technique of wooden building structures have not been studied intensively. This paper studies the use of nails and modified-washer to improve wood connection’s performance. The experimental tests were conducted in the laboratory by comparing the partial connection between test specimen timber without reinforcement (standard type) and the reinforcement (PRP type). The testing was conducted based on partial connection beam-column joint test using Universal Testing Machine’s with a modified holder. Wood studied includes Meranti (Shorea spp.) and Mersawa (Anisoptera spp.). PRP type connection was using nails and modified-washer strengthening, and standard type connection was using a classic washer. Parameters studied were strength and stiffness of the connection, reviewed both: proportional limit load and ultimate limit load conditions. Result obtained from this research indicates that the use of nails and modified-washer make a positive contribution to improving the performance of the beam�column timber joint connections, in terms of strength capacity (both of proportional limit and ultimate limit loads) and stiffness capacity (displacement ductility ratio). Meranti beam-column timber joint is more brittle than Mersawa beam column timber joint, it has an impact on the results. PRP-type of Mersawa timber connection produces a higher ductility than the standard type, while the PRP-type of Meranti timber connection produces a similar ductility to the standard type.

Item Type: Article
Contributors:
ContributionContributorsNIDN/NIDKEmail
UNSPECIFIEDPranata, Yosafat AjiUNSPECIFIEDUNSPECIFIED
UNSPECIFIEDKristianto, AnangUNSPECIFIEDUNSPECIFIED
UNSPECIFIEDPattipawaej, Olga CatherinaUNSPECIFIEDUNSPECIFIED
Uncontrolled Keywords: Partial test, beam-column joint, timber, nail and modified-washer, behavior.
Subjects: T Technology > T Technology (General)
Depositing User: Perpustakaan Maranatha
Date Deposited: 12 Apr 2023 09:58
Last Modified: 12 Apr 2023 09:58
URI: http://repository.maranatha.edu/id/eprint/31730

Actions (login required)

View Item View Item